Pad Mounted Transformer with Radial Feed
video
Pad Mounted Transformer with Radial Feed

Pad Mounted Transformer with Radial Feed

Pad Mounted Transformer with Radial Feed are designed with environmental considerations in mind. Modern units are often filled with biodegradable insulating oils or non-toxic dry-type insulation, minimizing environmental impact in case of leaks or spills.

Transpower Electrical Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of pad mounted transformer with radial feed in China. Welcome to buy high quality customized products at competitive price from our factory. Contact us for quotation.

 

Pad Mounted Transformer with Radial Feed

 

 

Available Supply

 

Power Rating

45kVA~6000kVA

Primary Voltage Ratings

up to 35kV

Secondary Voltage Ratings

up to 24.94kV

H.V. Tap Range

±2×2.5% or others

Connection Type

Delta/Wye

Winding Conductor

Copper or Aluminum

TYPE

Loop feed / Radial feed

Configuration

Live front / dead front

BIL

30-150kV

Standards

ANSI, IEEE, DOE, CSA, NEMA, UL

Application

Residential Areas, Hotels, Single Family Houses, Parks, Distribution Systems

Oil Type

Mineral Oil or Biodegradable Natural Vegetable Oil, Non PCB Fluid

Finish Color

Bell Green or as customized

Enclosure Rating

NEMA 3R Weatherproof Wiring Cabinet, Sealed Tank

 

GENERAL

 

Also know as a furface-mounted distribution transformer, the pad-mounted type derives its name from the concrete pad on which it rests. The unit is fully enclosed in a rugged, lockable steel housing that provides protection against unauthorized access and environmental damage.

 

Its primary duty within the distribution system is voltage transformation: It accepts medium-voltage power ( in the range of 2.4kV to 35kV) from underground feeders and reduces it to a lower utilization voltage (e.g., 415/240V for Australian consumers), serving residential, commercial, and industrial loads.

 

As a key asset in underground reticulation, it delivers a compact, weather-tight, and safe alternative to conventioanl pole-mounted transformers or larger substation installations, while maintaining high reliability and low maintenance.

 

Parameters

 

The following table is the standard parameter of the Pad Mounted Transformer with Radial Feed. If you need other capacity and voltage levels, please contact the TRANSpower to obtain accurate technical parameters and offers.

We provide customized Pad Mounted Transformer with Radial Feed according to customers.

Below Specs Are For Reference ONLY .

Three Phase Pad Mount Transformers Sizes

kVA

Type

HV

LV

W(mm)

D(mm)

H(mm)

75

radial

25000Delta

480GrdY/277

1280

1085

1085

150

loop

14400v

600GrdY/347

1480

1250

1750

225

radial

4160Delta

347GrdY/600V

1480

1295

1750

300

loop

345000

208GrdY/120

1500

1730

1850

500

loop

1247Grdy/7200V

600Y/347

1447

1800

1750

750

radial

24940GrdY/14400

800GrdY/462

1485

1730

1750

1,000

radial

249400DELTA

480V

1730

1350

1850

1,250

loop

25000V

416V

1730

1320

1920

1,500

loop

4160GRDY/2400

600GrdY/347

1730

1910

1965

1,500

loop

34500DELTA

480GrdY/277

2220

2069

2065

1,750

loop

13800Delta

480GrdY/277

1730

2304

1900

2,000

radial

4160DELTA

415GrdY/240

1730

1950

1810

2,500

loop

25000DELTA

600GrdY/347

1730

2560

1960

2,550

loop

12470DELTA

415GrdY/240

1730

2000

2200

2600

Loop

34500DELTA

416GrdY/240

1730

1695

2290

3000

Loop

27,600DELTA

13,800DELTA

1830

2360

2000

4000

loop

27600Delta

600GrdY/347

1900

2500

2010

5000

radial

13,800DELTA

4,160GrdY/2,400

1900

2735

2500

7000

loop

27,600DELTA

13,800DELTA

2200

3030

2080

7500

loop

249400DELTA

4.16kv Wye

2300

3200

2100

10000

loop

24900GrdY/14400

600V

2800

3500

2560

 

Main Materials

 

Silicone steel - 11

 

Coil

Pad mounted transformer
标题

 

Test & QC

 

After each unit of Pad Mounted Transformer with Radial Feed manufactured, routine tests/FAT will be carried out by the requirements of ANSI/IEEE C57.12.90 and C57.12.00. The test report comply with IEEE/CSA standards, and efficiency comply with DOE 2016 Standards.

 

Routing Test Items for Distribution Transformer

Resistance measurements of all windings on the rated voltage tap and at the tap extremes of the first unit of a new design

Ratio tests on the rated voltage connection and on all tap positions as listed on the nameplate

Polarity and phase relation tests on the rated voltage connection

No-load losses and excitation current at 100% of rated voltage and at rated power frequency on the rated voltage tap connection(s)

Impedance voltage and load loss at rated current and rated frequency on the rated voltage connection, and at the tap extremes of the first unit of a new design

Operation tests of all devices

Lightning impulse test

Low frequency test

Leak test

 

Design Test Item for Distribution Transformer

Temperature rise test at minimum and maximum ratings of the first unit of a new design

 

We offer both online and offline test supervision options for our customers. You can also choose a third party, such as SGS, CSA, or UL to visit Transpower's factory, during the witness test, the test being executed and receive a report that fully comply with standard requirements. Alternatively, you can request online video monitoring to observe the testing process in real-time. Ensuring transparency and confidence in the testing procedures.

Our production and testing equipment have professional calibration every year.

Test center

 

Pad Mounted Transformer with Radial Feed Outline

 

product-800-600
product-800-600

 

Painting

 

product-1500-844

 

Our Packages and Shippings

 

Assembly and Packaging Area

product-800-600
product-800-600

 

After Assembled then Shipping by container

product-800-600
product-800-600

 

Applications

 

Our Three Phase Pad Mount Transformers can be used in variety of applications, all ranging in complexity.

product-809-321

product-805-289

 

Frequently Asked Questions (FAQ)

 

Q: What Is The Difference Between Copper And Aluminum Windings Inside The Transformer?

A: Transformers wound with aluminum or copper wire have similar losses and performance. The choice of using copper or aluminum windings depends upon the application and the individual preferences. The type of winding material does not affect the transformer's reliability. A transformer's life is defined by the life of its insulation system.

Q: What are the environmental considerations?

A: Transformers should be installed with consideration for potential leaks of insulating oil. Using environmentally friendly fluids and adhering to local regulations regarding hazardous materials can help mitigate environmental impacts.

 

 

Hot Tags: pad mounted transformer with radial feed, China pad mounted transformer with radial feed manufacturers, suppliers, factory, transformer tools, transformer optimization, transformer stability, transformer magnetic flux, Pad Mounted Transformer With Radial Feed, transformer detectors

Send Inquiry