What causes the temperature rise in a power transformer?

Oct 14, 2025Leave a message

As a supplier of power transformers, I've witnessed firsthand the critical role these devices play in electrical systems. Power transformers are essential for stepping up or stepping down voltage levels, enabling efficient power transmission and distribution. However, one common issue that often concerns operators and end - users is the temperature rise in power transformers. In this blog, I'll delve into the various factors that cause this temperature increase.

Core Losses

The core of a power transformer is typically made of laminated silicon steel. When an alternating current passes through the primary winding, it creates a changing magnetic field in the core. This changing magnetic field induces eddy currents and hysteresis losses in the core.

Eddy currents are circulating currents induced within the core material. According to Faraday's law of electromagnetic induction, the changing magnetic flux in the core generates these currents. Since the core has some resistance, the eddy currents result in power dissipation in the form of heat. To minimize eddy current losses, the core is laminated. The thin laminations are insulated from each other, which increases the resistance of the path for eddy currents and reduces the heat generated.

Hysteresis losses occur due to the repeated magnetization and demagnetization of the core material as the alternating current changes direction. The magnetic domains in the core material need to realign with the changing magnetic field, and this process requires energy. The energy dissipated during this realignment is converted into heat, contributing to the temperature rise of the transformer. The quality of the core material and its magnetic properties significantly affect hysteresis losses. High - grade silicon steel with low hysteresis coefficients can reduce these losses.

Copper Losses

Copper losses, also known as I²R losses, are caused by the resistance of the transformer windings. When current flows through the windings, which are made of copper or aluminum conductors, heat is generated according to the Joule's law of heating (P = I²R), where P is the power dissipated as heat, I is the current flowing through the conductor, and R is the resistance of the conductor.

The resistance of the windings depends on several factors, including the material, cross - sectional area, and length of the conductors. As the load on the transformer increases, the current flowing through the windings also increases. Since the power loss is proportional to the square of the current, a small increase in current can lead to a significant increase in copper losses and, consequently, a rise in temperature. Additionally, the resistance of the conductors increases with temperature. As the windings heat up, their resistance further increases, causing even more heat to be generated in a self - reinforcing cycle.

Load Imbalance

In a three - phase power transformer, a balanced load is ideal. However, in real - world applications, load imbalances are common. When the loads on the three phases are not equal, the currents in the windings will also be unequal. This uneven distribution of current can lead to increased copper losses in the over - loaded phases.

For example, if one phase has a much higher load than the other two, the current in that phase will be significantly larger. According to the I²R formula, the power loss in that phase will be much greater than in the other phases, causing a localized temperature rise in the corresponding winding. Over time, this can lead to accelerated aging of the insulation in the over - heated winding and potentially reduce the overall lifespan of the transformer.

Cooling System Issues

Power transformers rely on cooling systems to dissipate the heat generated during operation. There are several types of cooling systems, including oil - immersed cooling, air - cooled systems, and water - cooled systems.

In oil - immersed transformers, the oil acts as both an insulating medium and a coolant. The oil absorbs the heat from the windings and core and transfers it to the radiator or heat exchanger. If the oil level is low, the cooling capacity will be reduced. Additionally, if the oil becomes contaminated or degraded over time, its heat - transfer properties will deteriorate. For instance, the presence of moisture in the oil can reduce its dielectric strength and heat - transfer efficiency.

Air - cooled transformers use fans to blow air over the windings and dissipate heat. If the fans malfunction or if the air intake and exhaust vents are blocked, the cooling effect will be impaired. Similarly, in water - cooled systems, issues such as a malfunctioning water pump, a clogged water pipe, or a decrease in water flow rate can lead to insufficient heat dissipation and a rise in transformer temperature.

Ambient Temperature

The ambient temperature around the transformer also has a significant impact on its operating temperature. Transformers are designed to operate within a certain temperature range, and when the ambient temperature is high, it becomes more difficult for the transformer to dissipate heat.

For example, in hot climates or during summer months, the surrounding air is already warm. This reduces the temperature difference between the transformer and the ambient air, which is the driving force for heat transfer. As a result, the cooling rate of the transformer decreases, and the temperature of the transformer can rise above its normal operating level. In some cases, additional cooling measures may be required to maintain the transformer's temperature within the safe range when the ambient temperature is extremely high.

Overloading

Operating a transformer beyond its rated capacity is a common cause of temperature rise. When a transformer is overloaded, the current flowing through the windings increases significantly. As mentioned earlier, copper losses are proportional to the square of the current. So, even a small amount of overloading can lead to a large increase in copper losses and heat generation.

Power Transformer3Power Transformer2

Overloading can occur due to unexpected increases in demand, improper sizing of the transformer during installation, or a malfunction in the power distribution system. Continuous overloading not only causes a rapid temperature rise but also accelerates the aging of the transformer's insulation. The insulation materials can degrade more quickly at high temperatures, reducing their dielectric strength and increasing the risk of electrical breakdown.

Insulation Degradation

The insulation in a power transformer is crucial for preventing electrical short - circuits between the windings and the core. Over time, the insulation can degrade due to factors such as high temperature, moisture, and electrical stress.

When the insulation degrades, its electrical properties change. For example, its dielectric constant may increase, leading to increased capacitive losses. These losses generate additional heat, contributing to the overall temperature rise of the transformer. Moreover, degraded insulation is more prone to partial discharges. Partial discharges are small electrical discharges that occur within the insulation material. These discharges generate heat and can further damage the insulation, creating a vicious cycle of insulation degradation and temperature increase.

Stray Losses

In addition to core and copper losses, there are also stray losses in a power transformer. Stray losses are caused by leakage fluxes that interact with conductive parts of the transformer, such as the tank, structural components, and bus bars.

The leakage fluxes induce eddy currents in these conductive parts, similar to the eddy currents in the core. These eddy currents result in power dissipation and heat generation. Minimizing stray losses requires careful design of the transformer, including proper shielding and placement of components to reduce the impact of leakage fluxes on conductive parts.

Impact on Transformer Performance and Lifespan

The temperature rise in a power transformer has a direct impact on its performance and lifespan. High temperatures can accelerate the aging of the insulation materials. The insulation in a transformer is designed to withstand a certain temperature limit. When the temperature exceeds this limit, the insulation can become brittle, crack, and lose its insulating properties.

This can lead to electrical breakdowns, which can cause short - circuits and damage to the transformer. Moreover, high temperatures can also affect the mechanical properties of the transformer components. For example, the expansion and contraction of the windings and core due to temperature changes can cause mechanical stress, leading to loose connections and potential failures.

Conclusion

As a power transformer supplier, I understand the importance of addressing the issue of temperature rise in transformers. By understanding the various factors that cause temperature increase, such as core losses, copper losses, load imbalances, cooling system issues, and ambient temperature, operators can take appropriate measures to ensure the safe and efficient operation of their transformers.

If you are in need of high - quality power transformers, we offer a wide range of products, including Power Grid High Voltage Transformer, Power Transformer in Power Plant, and Power Main Transformer. Our transformers are designed with advanced technology and high - quality materials to minimize temperature rise and ensure long - term reliability.

If you have any questions or are interested in purchasing power transformers, please feel free to contact us for a detailed discussion and procurement negotiation. We are committed to providing you with the best solutions for your power transmission and distribution needs.

References

  • Grover, F. W. (1973). Inductance Calculations: Working Formulas and Tables. Dover Publications.
  • Chapman, S. J. (2012). Electric Machinery Fundamentals. McGraw - Hill Education.
  • Westinghouse Electric Corporation. (1964). Electrical Transmission and Distribution Reference Book. Westinghouse Electric Corporation.
Send Inquiry